pure storage flasharray implementation specialist practice test

Exam Title: Pure Storage Certified FlashArray Implementation Specialist

Last update: Nov 27 ,2025
Question 1

A customer has a FlashArray X20R3 with 22/22 data packs in the chassis at 80% space usage and
wishes to swap one of the data packs for a 45TB pack. What step needs to be taken to facilitate this
consolidation?

  • A. Send a DirectFlash Shelf without any additional capacity.
  • B. Send a DirectFlash Shelf with a 63TB of temporary extra capacity.
  • C. Reduce array space usage to allow for the evacuation of the 22TB packs.
Answer:

B


Explanation:
Adding a DirectFlash Shelf with sufficient temporary extra capacity (63TB) allows data to be
evacuated from the smaller 22TB packs during the swap, enabling consolidation without reducing
array usage beforehand.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Question 2

An Implementation Engineer is onsite to install a new DFM data pack (DP) to CH0.BAY10-CH0.BAY19
of a FlashArray.
After adding the drives to the chassis, which command should the Implementation Engineer run to
verify if the new DP is in a wide write group?

  • A. find_drive.py
  • B. puredb list drives
  • C. puredrive list --pack CH0.BAY10
Answer:

C


Explanation:
The puredrive list --pack command shows detailed information about the specified data pack,
including whether its drives are part of a wide write group.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Question 3

What is the rack unit height of a FlashArray//XR2/3?

  • A. 3
  • B. 4
  • C. 5
Answer:

A


Explanation:
The FlashArray//XR2 and //XR3 models each occupy 3 rack units (RU) in height. This is specified in
the FlashArray//XR2 and //XR3 Site Planning Guide, which outlines the physical requirements for
rack space, clearance, and weight for these models.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Question 4

An Implementation Engineer is beginning a controller upgrade. Which command should be run to
stop Purity?

  • A. pureadm stop
  • B. pureadm stop --secondary
  • C. pureadm stop --controller CT0
Answer:

C


Explanation:
The command pureadm stop --controller CT0 specifically stops Purity on the designated controller
(CT0), which is the correct step to safely begin a controller upgrade.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Question 5

When transforming an array from SAS to NVMe with the Evergeen XFORM upgrade, when should a
swing shelf be installed?

  • A. When the chassis is populated with two data packs
  • B. When there is insufficient free space to evac capacity.
  • C. When the array is half populated with Flash Modules
Answer:

B


Explanation:
A swing shelf is installed during the SAS to NVMe Evergreen XFORM upgrade only if the array lacks
enough free capacity to evacuate data packs, enabling safe data migration during transformation.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Question 6

The Customer’s Implementation Workbook specifies that the SMTP reply is
“outlook.microsoft.com:587”. What correction should be made for array initialization to be
successful?

  • A. Provide username and password.
  • B. Prefix the URL with “https://”.
  • C. Remove the port number.
Answer:

C


Explanation:
For SMTP settings during array initialization, the host should be specified without the port number;
including “:587” can cause connection issues and prevent successful initialization.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Question 7

For FlashArray//XL, which 2 PCIe slots should be used for DFS connectivity?

  • A. 0 and 4
  • B. 0 and 6
  • C. 1 and 7
Answer:

B


Explanation:
On FlashArray//XL, PCIe slots 0 and 6 are designated for DirectFlash Shelf (DFS) connectivity to
optimize data throughput and redundancy.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Question 8

After running puredb run giveback --safe command once CT0 has been upgraded, how long should
the Implementation Engineer wait before continuing with the controller upgrade?

  • A. 3 minutes
  • B. 5 minutes
  • C. 10 minutes
Answer:

C


Explanation:
Waiting 10 minutes after running puredb run giveback --safe ensures the system completes safe
resource rebalancing and stabilizes before proceeding with the next controller upgrade step.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Question 9

Which command should an Implementation Engineer use to allow Support access to an array?

  • A. purearray connect --remoteassist
  • B. purearray remoteassist
  • C. purearray remoteassist --connect
Answer:

C


Explanation:
The purearray remoteassist --connect command explicitly enables Support to establish a remote
connection to the array for troubleshooting or assistance.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Question 10

A client needs to upgrade Purity on their FlashArray, but is unable to wait for an available upgrade
date from support.
What action should the customer take?

  • A. Open a ticket with support, download the latest Purity version, copy to a USB flash drive, and run the pureinstall command on each controller.
  • B. Log into the Purity CLI, download the latest Purity version, and run the pureinstall command on each controller.
  • C. Go through the Self-Service upgrade portal on Pure1 Manage and upgrade to the latest Purity version.
Answer:

C


Explanation:
Customers can independently upgrade Purity using the Self-Service upgrade portal on Pure1
Manage, enabling them to proceed without waiting for support scheduling.

vote your answer:
A
B
C
A 0 B 0 C 0
Comments
Page 1 out of 7
Viewing questions 1-10 out of 75
Go To
page 2