A customer is verifying that they have separation on their FC switch fabric to protect their FlexPod
solution from their other storage devices.
Which two technologies enable the customer to accomplish this task? (Choose two.)
A, D
A customer is deploying a FlexPod Datacenter and planning to boot from SAN each their UCS blades
using the Fibre Channel Protocol.
In this scenario, which three actions would accomplish their objective? (Choose three.)
A, B, E
A customer is unhappy with their current data center infrastructure. They want to purchase a FlexPod
system to replace it. The customer asks you to help them understand the benefits of Solution Support
to determine which support model would suit them best.
In this scenario, which three statements are correct? (Choose three.)
A, B, E
Your environment currently has a 12-node NetApp cluster serving iSCSI. You need to add at least four
more nodes to serve FC to your environment.
In this scenario, what should you do?
A
A customer wants to upgrade their code fabric between each site with a modular chassis switch that
supports up to 400GbE per port to accommodate more business transaction volume.
In this scenario, which device would help them accomplish their objective?
A
Reference:
https://www.cisco.com/c/en/us/solutions/data-center/high-capacity-400g-data-center-networking/index.html
You have a customer that wants to deploy a new data center environment and take advantage of
server portability. You propose that they use Cisco UCS servers to take advantage of stateless
computing operations.
In this scenario, which Cisco UCS feature would help the customer achieve their objective?
C
Reference:
https://community.cisco.com/t5/data-center-documents/what-is-stateless-computing-in-
ucs/ta-p/3116244
A customer has configured a FlexPod solution and is experiencing issues with connectivity from the
Cisco Nexus switches to the NetApp AFF controllers. The customer must verify connectivity using the
FC protocol.
What are two ways to troubleshoot this problem? (Choose two.)
B, C
A customer plans to decommission a Cisco UCS B-Series server, as part of this action, the customer
disassociates the service profile from the currently assigned server.
Which action is performed by UCS Manager in this scenario?
A
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ts/faults/reference/3-1/UCSFaultsErrorsRef_3-1/UCS_SEMs_3-1.html
Exhibit 1:

Exhibit 2:
Referring to the exhibit, UCS Fabric Interconnect 6300-A fails as shown in Figure 1. Due to the storage
LIF configuration, after UCS Fabric Interconnect 6300-A is restored, traffic flows as shown in Figure 2.
To enable this capability, on which two UCS port types should storage VLANs be accessible? (Choose
two.)
A, B
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-
Guides/Getting-Started/3-
2/b_UCSM_Getting_Started_Guide_3_2/b_UCSM_Getting_Started_Guide_3_2_chapter_010.pdf
(8)
You are designing a FlexPod solution with secure multitenancy for a company. Each department in
the company wants to use their own storage and to be integrated with Windows Active Directory.
In this scenario, which three technologies should be included in the design? (Choose three.)
B, D, E